        WARMFLO SELECT ELECTRIC PLENUM HEATERS

Warmflo Electric Plenum Heaters

(Download) Brochure       (Download) Owners Manual

(Download) Presentation

COMPLETE PRICING BELOW


The Warmflo Select Electric Plenum Heater series enhances overall heating system comfort, performance, and efficiency. Whether you are combining a gas or oil fired furnace or adding an air source heat pump, Warmflo can maximize your heating system's performance by monitoring outdoor and warm air plenum temperatures.  Complete all-inclusive controls make installation and follow-up service easy.  Using our dual energy selector makes switching fuels as easy as flip of the switch. 

 

      BASIC WARMFLO CONCEPT

 HOW DOES WARMFLO WORK WITH YOUR AIR SOURCE HEAT PUMP?

THE WARMFLO CONTROL RECEIVES TEMPERATURE INFORMATION FROM THE WARM AIR PLENUM SENSOR AND
THE OUTSIDE SENSOR TO MONITOR THE HEATING SYSTEM PERFORMANCE. USING DATA FROM THE SENSORS, THE WARMFLO INTELLIGENT CONTROLLER AUTOMATICALLY ESTABLISHES A WARM AIR DELIVERY TEMPERATURE IDEAL FOR THE SPECIFIC OUTDOOR TEMPERATURES.  AS THE OUTSIDE TEMPERATURE DROPS, THE AIR SOURCE
HEAT PUMP OUTPUT DECREASES AND THE WARM AIR REQUIRED TO HEAT YOUR HOME INCREASES.  THE WARMFLO PLENUM HEATER AUTOMATICALLY ADDS HEAT IN 500 WATT INCREMENTS TO MEET THE HEATING REQUIREMENTS OF THE HOME
.

     

When used with a Gas/Oil/Wood Furnace

 

When used with Heat Pump and Gas/Oil Furnace

  • Full Electric element modulation with target temperature output.

  • Simplified system control wiring

  • No high temperature audible alarm

  • Air Conditioning compatible

  • Full KW demand - does not come on unless required by outdoor temperature.

 

  • Overcomes heat pump "cold air syndrome"

  • Adjustable minimum warm air temperature

  • Proportional control - outlet temperature ramps up with decrease in outdoor temperature

  • Generally provides $400.00+ annual operating savings compared to dual fuel installations.

  • Provides a control technology for utilizing the high efficiencies of a heat pump down to at least 0 degrees F. 

Electrical

 

Standard Features

  • Spin Finned rod elements (20 year warranty)

  • Circuit Breakers

  • Electric utility control (heat and cool)

  • Variable speed blower connection

  • Single conventional 4 wire thermostat option

  • A/C control and no thermostat feedback

 

  • Application selection dial - HP or non - HP

  • All-inclusive controls, can be used with either heat pump or air conditioning

  • Modulates electric element to maintain  precise output temperatures

  • Quiet operation with individual DC relays

  • Energy control selector

  • 2 year parts warranty 

PRICING AND SPECIFICATIONS

WARMFLO SELECT PLENUM HEATER - ALL IN ONE PLENUM HEATER INCLUDES A BUILT IN INTERFACE, APPLICATION "SELECTOR SWITCH", AND CAN BE USED IN ANY HEATING APPLICATION (A/C OR SINGLE STAGE HEAT PUMP)  WIRING IS SIMILAR TO ORIGINAL WF-EZ3 AND WF-EM3 USING A SIMPLE 4 WIRE THERMOSTAT. NOT FOR USE WITH WF-HP2

                                                                             
                                          WARMFLO SELECT MODELS

UPFLOW 18"

UPFLOW 15"

KW @ 240 VAC

BTU/H

AMPS

CIRCUIT BREAKERS

OVER THE COUNTER PRICE

SHIPPED PRICE

EM-WU254S8-SL1
WARMFLO MODULATION,
4 STAGE

N/A

25 KW

85.000 104 60-60-30

$1530.00

$1630.00

EM-WU204S8-SL1
WARMFLO MODULATION,
4 STAGE

EM-WU204S5-SL1
WARMFLO MODULATION,
4 STAGE

20 KW

68.000 83 60-60

$1330.00

$1430.00

EM-WU153S8-SL1
WARMFLO MODULATION,
3 STAGE

EM-WU153S5-SL1
WARMFLO MODULATION,
3 STAGE

15 KW

51.000 62.5 60-30

$1230.00

$1330.00

EM-WU102S8-SL1
WARMFLO MODULATION,
2 STAGE

EM-WU102S5-SL1
WARMFLO MODULATION,
2 STAGE

10 KW

34.000 42 60

$1045.00

$1145.00

DOWNFLOW/
HORIZONTAL
18"

DOWNFLOW/
HORIZONTAL
15"

KW @ 240 VAC

BTU/H

AMPS

CIRCUIT BREAKERS

OVER THE COUNTER PRICE

SHIPPED PRICE

EM-WD254S8-SL1
WARMFLO MODULATION,
4 STAGE

N/A

25 KW

85.000 104 60-60-30

$1560.00

$1660.00

EM-WD204S8-SL1
WARMFLO MODULATION,
4 STAGE

EM-WD204S5-SL1
WARMFLO MODULATION,
4 STAGE

20 KW

68.000 83 60-60

$1360.00

$1460.00

EM-WD154S8-SL1
WARMFLO MODULATION,
3 STAGE

EM-WD154S5-SL1
WARMFLO MODULATION,
3 STAGE

15 KW

51.000 62.5 60-30

$1260.00

$1360.00

EM-WD102S8-SL1
WARMFLO MODULATION,
2 STAGE

EM-WD102S5-SL1
WARMFLO MODULATION,
2 STAGE

10 KW

34.000 42 60

$1060.00

$1160.00


 



 COPYRIGHT 2013 DJS ONLINE. ALL RIGHTS RESERVED

ABOUT US | BROCHURES | CONTACTS | CUSTOMER SUPPORT DJS ADS | FINANCING | PRIVATE POLICY | REBATES | SECURITY ISSUES |
SHIPPING PRODUCTS | SHOWROOM LOCATIONS |
SHIPPING OPTIONS | TERMS & CONDITIONS | TESTIMONIALS | SITE MAP | WEBSITE SECURITY
 


Send E-Mail to djs@djsonline.com with questions or comments about this web site.  Site Map