(DOWNLOAD) ETS FORCED AIR BROCHURE
(DOWNLOAD) ETS FORCED AIR MANUAL

LARGE ELECTRIC THERMAL STORAGE COMFORT
PLUS FORCED AIR HEATING SYSTEMS
    Forced Air Furnaces          Hydronic Furnace          


                RESIDENTIAL AND SMALL COMMERCIAL PRODUCTS

If you are looking for comfort, convenience and affordability from your heating system, off-peak heating with ETS is for you.
Heating with off-peak ETS is most economical in areas where the power company offers off-peak or time-of-use electric rates.
Compared to unstable gas prices, you'll find heating with off-peak ETS is a fraction of the cost.

                           Many reasons to consider using an off-peak ETS heating system.

  • Low cost heating option

  •  Safe form of heating

  • Stable and predictable rates

  • No need to remember to fill a tank

  • Pay for consumption after using it

  • No need for a carbon monoxide detector

  • Requires no routine maintenance
    outside of changing air filters

  • Clean and reliable

  • No house chimney required

Comfort Plus Forced Air Heating
System Information & Pricing

Forced Air Furnaces

The Comfort Plus unit is designed to be the main heating system (forced air) for residential or small commercial applications. The Comfort Plus unit can be used as a stand alone furnace or can be installed with a heat pump to realize even greater efficiency and energy savings. It is a versatile appliance that can serve as a back-up for an electric furnace during on-peak times, replace a duct heater, or supplement a fossil fuel system. During of-peak hours, the Comfort Plus unit converts electricity into heat and stores that heat in specially designed, high density ceramic bricks. The Comfort Plus system has the heat storage capacity to provide total comfort 24 hours a day, while allowing the user to utilize low cost off-peak electric rates to achieve very economical and affordable heating.

The Comfort Plus unit is easy to operate. The amount of heat stored in the brick core is automatically regulated in relation to outdoor temperature and the heating requirements of the user. When the room thermostat calls for heat, heat is extracted from the unit's storage core and is distributed evenly into the home until the heat call has been satisfied.

The Comfort Plus unit has sensing devices that monitor the core, the supply and the discharge air temperatures to ensure maximum safety while providing optimum comfort. A heat pump, air conditioner, electronic air cleaner, central humidifier, programmable thermostat, etc., can easily be integrated to offer year round comfort.

 FOUR MODELS AVAILABLE - 1KW = 3412 BTU/HR   1 KWH = 3412 BTU
MODEL 3120 4120 4130 4140

PRICE

$3185.00

$3815.00

$4295.00

$4660.00

CHARGING INPUT

14.0KW 17.5KW 21.6KW
19.2KW 24.8KW
28.8KW 37.2KW
38.4KW 45.6KW

ELEMENTS CURRENT DRAW (AMPS)

59 73 90
80 104
120 155
160 190

CIRCUITS REQUIRED (ELEMENTS)

2-40 AMP 2-50 AMP 2-60 AMP
3-40 AMPS 3-50 AMPS
4-40 AMPS 4-50 AMPS
4-50 AMPS 4-60 AMPS

CIRCUITS REQUIRED (BLOWERS/CONTROL)

1-15 AMP 1-15 AMP 1-15 AMP
1-15 AMP 1-15 AMP
1-15 AMP 1-15 AMP
1-15 AMP 1-15 AMP

UNIT IS FACTORY CONFIGURED WITH MULTIPLE-LINE VOLTAGE, SINGLE-PHASE CIRCUIT CONNECTIONS.  IF THE SINGLE FEED TO THE ELEMENT AND BLOWERS/CONTROLS CIRCUITS IS DESIRED, AN OPTIONAL SINGLE-FEED KIT IS AVAILABLE.  PHASE-BALANCING IS RECOMMENDED WHEN MAKING CONNECTIONS IN 3-PHASE APPLICATIONS.

STORAGE CAPACITY

86 KWH (293,432 BTU 125 KWH (426,500 BTU) 180 KWH (614,160 BTU) 240 KWH (818,880 BTU)

The size and heating ability of the system required for an application is dependent on the heat loss of the area and the power company's off-peak hours. In addition, if the unit is not installed within the heated area, heat lost statically must be taken into account. Contact your local power company, a contractor, or Steffes Corporation for assistance in selecting an appropriately sized system.

APPROXIMATE INSTALLED WEIGHT

1,562 LBS 2,183 LBS 3,031 LBS 3,859 LBS

DUCT OPENING
   SUPPLY AIR OUTLET
(1/2 HP BLOWER)
   RETURN AIR INLET

10.1" x 16"
21.4" x 21.4"
(factory built plenum)

18" x 22.6" (in factory built plenum)
10.5" x 22.3" (in unit) or 21.4" x 21.4"
(if using factory built
plenum)  
18" x 22.6" (in factory built plenum)
10.5" x 22.3" (in unit) or 21.4" x 21.4"
(if using factory built
plenum)  
18" x 22.6" (in factory built plenum)
10.5" x 22.3" (in unit) or 21.4" x 21.4"
(if using factory built
plenum)  

MAXIMUM COIL SIZE
(W x D x H)

21" x 21" x 24.25"

21" x 21" x 24.25"

21" x 21" x 24.25"

21" x 21" x 24.25"

The factory-built return air plenum is configured for housing an indoor coil. Dimensions listed are that of the inner coil area in this plenum. For larger coils, field provisions to the plenum are necessary or it will need to be supplied by the installer.


OPTIONAL ITEMS:

1/2 HP VARIABLE SPEED BLOWER $595.00
1 HP VARIABLE SPEED BLOWER - 4100 SERIES $735.00
RETURN AIR PLENUM - 4100 SERIES $200.00
DOWN FLOW AIR PLENUM KIT - 4100 SERIES
$60.00

 