DUCTLESS MINI-SPLIT SYSTEMS
WITH INVERTER TECHNOLOGY
UP TO 19 SEER! - V SERIES SINGLE ZONE

(DOWNLOAD) BROCHURE

(DOWNLOAD) OWNER'S MANUAL

COMFORT-AIRE IS KNOWN THROUGHOUT THE HEATING AND AIR CONDITIONING INDUSTRY FOR EFFICIENT, RELIABLE PRODUCTS AND IN-SEASON AVAILABILITY.  WHETHER FOR HEATING OR COOLING, THESE PRODUCTS MEET OR EXCEED INDUSTRY STANDARDS FOR ENERGY EFFICIENCY.  THE LINE IS CONSTANTLY BEING UPDATED TO ADD THE FEATURES AND NEW TECHNOLOGY THAT CUSTOMERS DEMAND.

DUCTLESS MINI-SPLITS ARE ONE OF THE FASTEST GROWING GROUPS, AND THERE ARE MANY REASONS FOR THIS INCREASING POPULARITY - BUT OVERALL, THE KEY IS FLEXIBILITY.  COMFORT-AIRE ALLOWS AIR CONDITIONING (AND HEATING WITH HEAT PUMP MODELS) TO BE QUICKLY, CONVENIENTLY AND ECONOMICALLY - OFTEN IN LOCATIONS WHERE INSTALLING SUCH COMFORT SYSTEMS DIDN'T SEEM POSSIBLE OR PRACTICAL.

FREE SHIPPING ON ALL COMFORT-AIRE UNITS!
9.000BTU UP TO 27.000BTU - COMPLETE PRICING BELOW

Comfortaire Ductless Inverter V System

 

 

 

 

 

 

 

 

 

    6 YEAR COMPRESSOR WARRANTY 
      AND 2 YEAR PARTS WARRANTY


V SERIES INVERTER TECHNOLOGY IN A WIDE RANGE OF CAPACITIES. COMFORT AND ENERGY EFFICIENCY COMBINE IN THESE ATTRACTIVE WALL MOUNT MINI-SPLITS.  RATED AS HIGH AS 19.1 SEER, THEY INCLUDE ALL THE ADVANTAGES OF ADVANCED INVERTER COMFORTAIRE TECHNOLOGY. YOU'LL FIND THAT YOUR ROOM REACHES THE PRESET TEMPERATURE QUICKLY AND THAT THE TEMPERATURE IS CONSTANT, WITHOUT THE VARIATIONS THAT OCCUR IN OTHER TYPES WITH ON-OFF CYCLING.  BECAUSE THE UNITS RUN AT "ECONOMY" SPEED MOST OF THE TIME, ENERGY USAGE IS KEPT TO A MINIMUM. HOWEVER, DURING WEATHER EXTREMES (OR WHEN YOU HAVE A ROOM FULL OF PEOPLE), THE COMPRESSOR RAMPS UP AUTOMATICALLY TO MAINTAIN THE COMFORT LEVEL.

COMFORTAIRE MINI-SPLITS ARE THE IDEAL SOLUTION FOR CONDITIONING AREAS WHERE ADDING DUCTWORK IS IMPRACTICAL OR TOO EXPENSIVE. THIS INCLUDES OLDER HOMES, BEDROOMS, SUNROOMS, ADDITIONS, OFFICE SPACES, COMPUTER ROOMS, SPORTS ARENA SKYBOXES, AND INTERIOR WAREHOUSE OFFICES, TO NAME JUST A FEW.

COMFORTAIRE MINI-SPLITS ARE EASILY INSTALLED WITH THE CONDENSING UNIT LOCATED OUTSIDE AND THE AIR HANDLER(S) MOUNTED INSIDE. A HOLE LESS THAN 3" IN DIAMETER IS ALL THAT'S REQUIRED TO CONNECT LINES AND WIRES BETWEEN THE OUTDOOR AND INDOOR COMPONENTS. UNITS COME PRE-CHARGED WITH ENVIRONMENTALLY FRIENDLY R-410A FREON.

FEATURES OF THE COMFORTAIRE V SERIES
INVERTER MINI-SPLIT UNITS

  • ATTRACTIVE CABINET - INDOOR UNITS FEATURE A SLIM PROFILE WITH ROUNDED CORNERS AND SLEEK GRILLES WITH A SUBTLE METALLIC LOOK PANEL

  • MULTIPLE MODES - COOLING, DEHUMIDIFICATION ONLY, AND HEATING IN HEAT PUMP MODELS. SLEEP MODE, 24-HOUR TIMER, JET COOL, AUTO SLEEP MODE, HOT START (HEAT PUMP MODELS)

  • RANDOM SWING - CONTINUALLY ADJUSTS FAN SPEED AND AIR DIRECTION FOR A GENTLE, BREEZE LIKE EFFECT THAT'S PREFERRED BY MOST PEOPLE.

  • REMOTE CONTROL - MAKES IT EASY TO PROGRAM AND OPERATE THE UNIT.

  • MULTI-STAGE FILTRATION - INCLUDES ELECTROSTATIC FILTER, ANTIFUNGAL FILTER AND DEODORIZING FILTER FOR IMPROVED INDOOR AIR QUALITY.

  • LOW AMBIENT OPERATION - COOLING MODE FUNCTIONS EVEN WHEN THE OUTDOOR TEMPERATURE REACHS 0 DEGREES

  • DEFROST CONTROL - REMOVES ANY FROST ACCUMULATION ON THE COIL OF HEAT PUMPS

  • AUTO RESTART - REVERTS TO THE LAST SETTING FOLLOWING A POWER FAILURE   

LOW AMBIENT OPERATION

COOLING ONLY MODELS CAN BE USED IN APPLICATIONS WHERE OUTSIDE TEMPERATURES ARE VERY LOW AND THE INDOOR SPACE, SUCH AS A SERVER ROOM, STILL REQUIRES AIR CONDITIONING.

  • OPERATION AT RATED CAPACITY FROM 0-110F OUTDOOR AIR TEMPERATURE

  • OPERATION WITH DECREASED CAPACITY FROM 110-120 OUTDOOR AIR TEMPERATURE

HEAT PUMP MODEL DELIVER SUPERIOR HEAITNG PERFORMANCE COMPARED TO NON-INVERTER MINI-SPLITS, PROVIDING MORE HEAT AT LOWER TEMPERATURES. 

  • OPERATION AT RATED CAPACITY FROM 23-75 F OUTDOOR AIR TEMPERATURE

  • OPERATION WITH DECREASED CAPACITY FROM 14-23F OUTDOOR AIR TEMPERATURE.

 

 


                        COMPLETE SPECIFICATIONS AND PRICING
                  
            COOLING ONLY AND HEAT PUMP UNITS
                                                                                  PLEASE CONTACT US TO ORDER!
                           

COOLING   MODELS >

VMC09SB-1 VMC12SB-1 VMC18SB-1 VMC24SB-1 VMC30SB-1

SHIPPED PRICE

 $1,249.00 $1,299.00 $1,549.00 $1,749.00 $2,299.00
POWER SUPPLY 208/230/1-60 208/230/1-60 208/230/1-60 208/230/1-60 208/230/1-60
COOLING BTU 9,200 12,000 18,000 24,000 26,400/27,000
SEER 19.1 18.6 16.0 16.0 16.0
COOLING AMPS 3.5/3.2 5.5/5.0 8.0/7.3 12.1/11.0 13.6/12.5
DEHUMIDIFY 3.2 3.2 4.4 5.7 7.2
HEATING CAP. BTU N/A N/A N/A N/A N/A
HEATING AMPS N/A N/A N/A N/A N/A
HSPF N/A N/A N/A N/A N/A
INDOOR UNIT          
AIR FLOW (CFM) 300 335 494 565 710
FAN SPEEDS 4 4 4 4 4
AIR DIRECTION          
VERTICAL MODULATING MANUAL MANUAL REMOTE REMOTE REMOTE
HORIZONTAL (LEFT/RIGHT) MANUAL MANUAL REMOTE REMOTE REMOTE
RANDOM SWING STANDARD STANDARD STANDARD STANDARD STANDARD
INDICATOR LAMPS          
ON/OFF STANDARD STANDARD STANDARD STANDARD STANDARD
24 HR. TIMER/SLEEP MODE STANDARD STANDARD STANDARD STANDARD STANDARD
TEMP SETTING STANDARD STANDARD STANDARD STANDARD STANDARD
INDOOR UNIT DIMENSIONS          
WIDTH 35 1/4" 35 1/4" 43" 43" 47 3/5"
HEIGHT 11 1/8" 11 1/8" 11 4/5" 11 4/5" 13 3/5"
DEPTH 6 1/2" 6 1/2" 7" 7" 8 1/16"
OUTDOOR UNIT DIMENSIONS          
WIDTH 30 1/3" 30 1/3" 34 1/3" 34 1/3" 34 1/4"
HEIGHT 21 1/3" 21 1/3" 25 4/5" 31 1/2" 31 1/2"
DEPTH 9 3/5" 9 3/5" 12 3/5" 12 3/5" 12 3/5"
ELECTRICAL DATA OUTDOOR UNIT          
MAIN POWER CONNECTION OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT
MAX.CIRCUIT AMP 8.2 9.9 12.4 16.7 17
MAX FUSE/HACR CIR.BREAKER 15 15 20 25 30
RECOMMENDED INDOOR/OUTDOOR CONNECTING CABLE

LINE VOLTAGE PER NEC*

LINE VOLTAGE PER NEC*

LINE VOLTAGE PER NEC*

LINE VOLTAGE PER NEC*

LINE VOLTAGE PER NEC*

LINESETS          
REFRIGERANT R410A R410A R410A R410A

R410A

LIQUID FLARE 1/4  1/4 1/4 3/8 1/4
SUCTION FLARE 3/8 3/8 1/2 5/8 5/8
MAX LENGTH 49 FT 49 FT 49 FT 98 FT 98 FT
MAX ELEVATION  25 FT 25 FT 49 FT 49 FT 25 FT

HEAT PUMP MODELS >

VMH09SB-1 VMH12SB-1 VMH18SB-1 VMH24SB-1 VMH30SB-1

SHIPPED PRICE

$1,349.00 $1,499.00  $1,699.00 $1,899.00 $2,449.00
POWER SUPPLY 208/230/1-60 208/230/1-60 208/230/1-60 208/230/1-60 208/230/1-60
COOLING BTU 8,950/9,200 11,700/12,000 17,500/18,000 23,400/24,000 26,400/27,000
SEER 19.1 18.6 16.0 16.0 16.0
COOLING AMPS 3.5/3.2 5.5/5.0 8.0/7.3 12.1/11.0 13.6/12.5
DEHUMIDIFY 3.2 3.2 4.4 5.7 7.2
HEATING CAP. BTU 11,700/12,000 15,100/15,500 20,200/20,700 26,600/27,300 28,300/29,000
HEATING AMPS 4.6/4.2 6.5/5.9 9.1/8.3 14.0/13.0 14.0/12.7
HSPF 9.5 9.5 8.2 8.2 8.0
INDOOR UNIT          
AIR FLOW (CFM) 300 335 494 565 710
FAN SPEEDS 4 4 4 4 4
AIR DIRECTION          
VERTICAL MODULATING MANUAL MANUAL REMOTE REMOTE REMOTE
HORIZONTAL (LEFT/RIGHT) MANUAL MANUAL REMOTE REMOTE REMOTE
RANDOM SWING STANDARD STANDARD STANDARD STANDARD STANDARD
INDICATOR LAMPS          
ON/OFF STANDARD STANDARD STANDARD STANDARD STANDARD
24 HR. TIMER/SLEEP MODE STANDARD STANDARD STANDARD STANDARD STANDARD
TEMP SETTING STANDARD STANDARD STANDARD STANDARD STANDARD
INDOOR UNIT DIMENSIONS          
WIDTH 35 1/4" 35 1/4" 43" 43" 47 3/5"
HEIGHT 11 1/8" 11 1/8" 11 4/5" 11 4/5" 13 3/5"
DEPTH 6 1/2" 6 1/2" 7" 7" 8 1/16"
OUTDOOR UNIT DIMENSIONS          
WIDTH 30 1/3" 30 1/3" 34 1/3" 34 1/3" 34 1/4"
HEIGHT 21 1/3" 21 1/3" 25 4/5" 31 1/2" 31 1/2"
DEPTH 9 3/5" 9 3/5" 12 3/5" 12 3/5" 12 3/5"
ELECTRICAL DATA OUTDOOR UNIT          
MAIN POWER CONNECTION OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT
MAX.CIRCUIT AMP 8.2 9.9 12.4 16.7 17
MAX FUSE/HACR CIR.BREAKER 15 15 20 25 30
RECOMMENDED INDOOR/OUTDOOR CONNECTING CABLE

LINE VOLTAGE PER NEC*

LINE VOLTAGE PER NEC*

LINE VOLTAGE PER NEC*

LINE VOLTAGE PER NEC*

LINE VOLTAGE PER NEC*

LINESETS          
REFRIGERANT R410A R410A R410A R410A

R410A

LIQUID FLARE 1/4  1/4 1/4 3/8 1/4
SUCTION FLARE 3/8 3/8 1/2 5/8 5/8
MAX LENGTH 49 FT 49 FT 49 FT 98 FT 98 FT
MAX ELEVATION  25 FT 25 FT 25 FT 25 FT 25 FT

 
                         Refrigeration Linesets - Both lines are insulated (Need 2 Lines)
                                    Each system is pre-charged with enough refrigerant to charge 25' of line and the interior unit.

Linesets 25ft 50ft
1/4 x 3/8  $109.99 $179.99
1/4 x 1/2 $119.99 $189.99
1/4 x 5/8 $129.99 $199.99
3/8 x 5/8  $139.99 $219.99

 

                                      Perma Pad A/C Slabs

Pad Size Price
Pads are a base for the outdoor air conditioner or heat pump unit to sit on. They are made of 2 inch thick plastic and are very rigid. The plastic has ultraviolet inhibitors in it so it will not break down in sunlight.  24 x 36 $34.99

                                        